    2.5mm2 Solid Copper Conductor Ground Earth Solid Thhn Flame Retardant

    Ask Lasest Price
    Supply Ability : 100000 meters per month
    Brand Name : TONGDU
    Model Number : BV-2.5mm²
    Payment Terms : L/C,T/T
    Delivery Time : Less than 15 days
    Certification : CE/ISO/CCC
    • Product Details
    • Company Profile

    2.5mm2 Solid Copper Conductor Ground Earth Solid Thhn Flame Retardant

    Yellow Green BV 2.5mm² Ground Earth Wire PVC Insulated Copper Cable

    Cable Designation & Meaning

    Code

    Meaning

    B

    Fixed wiring cable (Class B — building wire)

    V

    PVC (polyvinyl chloride) insulation

    2.5 mm²

    Nominal cross-sectional area of conductor


    Construction: Plain copper conductor (solid or stranded), PVC insulation, single-core non-sheathed building wire.

    Applicable Standards

    • GB/T 5023-2008 / IEC 60227 — Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V
    • GB/T 3956 / IEC 60228 — Conductors (Class 1 solid or Class 2 stranded, copper)
    • GB/T 18380 / IEC 60332 — Flame retardant tests
    • GB/T 2951 / IEC 60811 — Insulating and sheathing materials — Common test methods

    BV-2.5 mm² (green-yellow striped, PE protective earth — IEC 60446 / GB 7947) — Copper PVC-Insulated Building Wire Specification & Engineering Data

    1. Product Overview & Rating Summary. BV-2.5 (green-yellow striped) is the standard Chinese copper PVC-insulated building wire rated 450/750 V AC for interior fixed wiring, built and tested per GB/T 5023 / JB/T 8734. This is the IEC 60446 / GB 7947 standard PE (protective earth) conductor colour — green-yellow diagonal stripes. Unlike solid green (used for specific bonding applications), green-yellow striped is reserved EXCLUSIVELY for protective earthing and must never be used for phase, neutral, or control circuits. Finished diameter is about 3.6 mm, mass about 22 kg/km, supplied in 100 m coils.


    2. Layer-by-Layer Construction (Conductor to Outer).

    LayerConstructionWallDiameter
    ConductorSolid round annealed copper wire, Class 1—1.78 mm
    InsulationPolyvinyl chloride (PVC), green-yellow striped0.8 mm≈ 3.6 mm (finished)
    Outer sheathNone — insulation is the outer layer——

    3. Electrical Characteristics. The 2.5 mm² conductor is a solid 1.78 mm annealed copper wire (Class 1, not stranded), giving a maximum DC resistance of 7.41 Ω/km at 20 °C. Routine proof is 2.0 kV AC / 5 minutes. Insulation resistance ≥ 0.011 MΩ·km. With the single core in free air at 30 °C, reference loading is about 24 A; in conduit with three grouped cores, the rating derates to about 19 A. For PE circuits, low loop resistance is critical to ensure protective devices operate during earth faults. Conductor loss at 24 A is about 4.3 W per metre at 70 °C.

    Insulation Data

    Property

    Value

    Material

    PVC (polyvinyl chloride)

    Nominal thickness

    0.8 mm

    Long-term service temp.

    70 °C (continuous)

    Short-circuit temp. (≤5 s)

    160 °C​ (Cu conductor limit per IEC 60228)

    Emergency overload temp.

    90 °C (short term)

    Weather resistance

    Limited — for indoor/dry use only; not UV-resistant

    Flame retardant

    GB/T 18380.3 Category C (ZC) available; standard version passes IEC 60332-1

    Smoke density

    Standard (non-low-smoke)

    Halogen content

    Contains halogen (PVC)

    Corrosivity

    Corrosive (PVC)

    Electrical Parameters

    Parameter

    Value

    Note

    Rated voltage U₀/U

    450 / 750 V

    GB/T 5023 / IEC 60227

    Test voltage AC (50 Hz, 5 min)

    2500 V

    Routine test

    DC resistance @20 °C

    ≤ 7.41 Ω/km

    GB/T 3956 Class 1 max, 2.5 mm² (solid Cu)

    AC resistance @70 °C (est.)

    ≈ 9.40 Ω/km

    per core

    Capacitance (approx.)

    negligible

    single-core building wire

    Inductive reactance (approx.)

    negligible

    —

    Current rating in conduit (30 °C ambient)

    24 A​

    single-phase, 2-core circuit (GB/T 16895)

    Current rating in free air (30 °C)

    27 A​

    single cable

    Current rating buried (20 °C)

    22 A​

    direct in soil (not recommended)

    Short-circuit current (1 s, Cu, 160 °C)

    ≈ 0.25 kA (250 A)

    2.5 mm² Cu

    Frequency

    50/60 Hz AC

    —

    Reference values: 2.5 mm² Cu at 24 A, single-phase 230 V → max load ≈ 5.5 kW. Voltage drop at 24 A ≈ 17.8 V/km per core (≈0.78% per 10 m at 230 V).

    Temperature Characteristics

    Property

    Value

    Max. conductor operating temp.

    70 °C (continuous)

    Max. short-circuit temp. (≤5 s)

    160 °C (Cu conductor)

    Emergency overload temp.

    90 °C (short term)

    Min. installation ambient temp.

    0 °C (PVC insulation); below 0 °C pre-heating required

    Service ambient range

    −15 °C to +70 °C (indoor/dry)

    Fire survival

    Standard (non-fire-rated); optional fire-resistant version available (BTTZ, BTTRZ)


    4. Thermal Response & Flame Behaviour. PVC insulation sustains a 70 °C continuous conductor temperature, with short-circuit capability up to 160 °C for ≤ 5 s. The cable is rated for service ambients between 0 °C and +70 °C and must not be installed below 0 °C (PVC becomes brittle). It is flame-retardant to GB/T 18380 / IEC 60332-1 (self-extinguishing). PVC contains halogen — not halogen-free; for low-smoke halogen-free earthing in public buildings, use WDZ-BYJ (also green-yellow striped) instead.

    Fire Performance (BV — Standard)

    Property

    Value / Requirement

    Flame retardant

    GB/T 18380.3 Category C (ZC), Category B (ZB) available

    Halogen content

    Contains halogen (PVC insulation)

    Smoke density

    Standard (non-low-smoke)

    Corrosivity

    Corrosive (PVC)

    Fire survival (circuit integrity)

    Not applicable (standard version); use mineral-insulated or fire-resistant building wire


    5. Installation Practice & Handling. Minimum bend radius is 4 × OD (≈ 14 mm) for fixed installation. The solid conductor is rigid and designed for fixed installation only. Install inside conduit, trunking, or wall conduit — do not leave exposed outdoors. Use earth lugs / socket PE terminals for low-resistance bonding. CRITICAL: green-yellow striped is PE ONLY — never use for phase, neutral, or control. Laying temperature must not fall below 0 °C.

    Mechanical & Installation Parameters

    Parameter

    Value

    Remarks

    Minimum bending radius

    ≥ 4 × OD → ≈ 14 mm at Ø3.5 mm

    static installation

    Max. pulling tension

    100 N

    solid Cu conductor, avoid sharp bends

    Conduit ID

    ≥ 1.5 × OD → ≥ 5.3 mm; use 16 mm or 20 mm conduit

    standard building conduit

    Fixing

    cable clips, conduit, trunking

    —

    Impact resistance

    Low

    not armoured; protect with conduit

    Water resistance

    Poor

    indoor/dry locations only

    UV resistance

    Poor

    not for outdoor exposed use

    Termination note

    Strip insulation 10–12 mm; use standard copper lugs or screw terminals

    solid conductor requires careful handling to avoid breakage


    6. Typical Service Applications. This green-yellow BV-2.5 is the standard PE wire for: PE protective earthing, socket outlet earth terminals, distribution board PE busbar, equipment metal casing grounding, cable armour earthing, earth fault return path. Unlike solid green (used for specific bonding), green-yellow striped is the internationally recognised PE conductor — used for socket outlet earth terminals, distribution board PE bars, and equipment metal casing grounding. It is installed inside conduit or trunking — never outdoors.



    7. Testing & Quality Assurance Regime. Routine tests on every coil include conductor DC resistance ≤ 7.41 Ω/km at 20 °C, the 2.0 kV AC / 5 min withstand, dimensional check (insulation ≥ 0.8 mm; OD ≈ 3.6 mm), and visual marking. Type tests include heat ageing (100 °C / 168 h), cold bend at 0 °C, heat shock at 150 °C, flame retardancy per GB/T 18380 / IEC 60332-1, insulation resistance, conductor continuity, and colour check (green-yellow striped per IEC 60446).


    The Wire Parameters


    BV-2.5 mm² (green-yellow striped) — Copper PVC-Insulated Building Wire — Full Parameter Sheet
    Copper PVC-insulated building wire · solid Class 1 conductor / green-yellow striped PVC insulation · 450/750 V AC · PE protective earthing (IEC 60446 / GB 7947 standard colour) · GB/T 5023 / JB/T 8734 · finished Ø ≈ 3.6 mm
    SectionParameterValueUnitRemarks / Standard
    01 · Identification
    Cable typeBV (Copper PVC-insulated building wire)—PE protective earthing, single core
    Rated voltage (U0/U)450/750V ACFor building interior fixed wiring
    Number of cores1 × 2.5—Single core
    Conductor materialAnnealed solid copper—Class 1 solid per GB/T 3956
    Insulation materialPolyvinyl chloride (PVC)—PVC-70 °C grade, green-yellow striped
    Outer sheathNone—Single-layer insulation, no outer sheath
    ColourGreen-yellow striped—PE protective earthing colour (IEC 60446 / GB 7947)
    StandardGB/T 5023 / JB/T 8734 / GB 7947—Chinese building wire + earthing colour standard
    02 · Conductor (Solid Copper)
    Conductor typeSolid round copper wire—Class 1 solid per GB/T 3956
    Conductor diameter1.78mmSolid single wire
    Cross-sectional area2.5mm²Nominal
    DC resistance @ 20 °C≤ 7.41Ω/kmMaximum per GB/T 3956
    Conductor screenNone—LV building wire
    Conductor weight per km≈ 22kg/kmCopper density 8.89 g/cm³
    03 · Insulation (PVC)
    Insulation typePolyvinyl chloride (PVC)—PVC-70 °C grade, green-yellow striped
    Insulation thickness0.8mmNominal
    Finished outer diameter≈ 3.6mm1.78 + 2×0.8
    ColourGreen-yellow striped—PE protective earthing colour (IEC 60446 / GB 7947)
    Outer sheathNone—No outer sheath — insulation is the outer layer
    04 · Electrical
    Rated voltage (AC)450/750VFor building interior fixed wiring
    DC resistance @ 20 °C≤ 7.41Ω/km2.5 mm² Cu Class 1
    Insulation resistance≥ 0.011MΩ·kmPVC at 20 °C
    Conductor loss (at 24 A)≈ 4.3W/mI²R at 70 °C
    Routine test voltage (AC)2.0 kV / 5 min—Power-frequency withstand
    Voltage test (AC)2.5 kV / 5 min—AC withstand test
    05 · Thermal
    Max continuous conductor temp.70°CPVC rated
    Short-circuit temp.160°CPVC limit (≤ 5 s)
    Min installation temp.0°CPVC becomes brittle below 0 °C
    Service ambient range0 to +70°CIndoor dry locations
    UV resistanceNone—Indoor use only — not UV resistant
    Ozone resistanceLimited—Indoor use only
    Halogen-freeNo—PVC contains halogen
    Flame retardancyIEC 60332-1 / GB/T 18380—Self-extinguishing
    06 · Mechanical
    Min bending radius (fixed)≥ 4 × OD ≈ 14mmFixed installation
    Tensile strength (insulation)≥ 10.0MPaPVC insulation
    Abrasion resistanceGood—Indoor conduit / trunking
    Oil / fuel resistanceNo—Indoor dry locations only
    07 · Ampacity
    Air ampacity (open, 30 °C)≈ 24ASingle core, free air (est.)
    Conduit ampacity (3-core)≈ 19AIn conduit, grouped
    Voltage drop (per 100 m @ 24 A)≈ 1.8VSingle-phase loop ≈ 3.6 V
    08 · Installation
    Laying methodsConduit, trunking, wall conduit, PE busbar, socket earthing—Indoor fixed installation
    ConnectorsEarth lugs, screw terminals, socket earth terminals—Standard earthing connections
    PolarityColour-coded—Green-yellow = PE only — must NOT be used for other purposes
    Special toolsWire cutter, stripper, screwdriver—Standard electrical tools
    09 · Packing
    Standard supply length100 m / coilmBuilding wire
    Reel / packing typeCoil / carton—Standard packaging
    Surface markingBV, 2.5 mm², 450/750 V, GB/T 5023, metre marks—Continuous printing
    Storage conditionsDry, indoor, 0 to +40 °C—Protect from UV / moisture
    10 · Applications
    Typical usePE protective earthing, socket outlet earth terminals, distribution board PE busbar, equipment metal casing grounding, cable armour earthing, earth fault return path—Indoor fixed wiring
    Max system voltage750V AC450/750 V rated
    Circuit current ratingUp to 24APer circuit breaker

    The Wire Test Parameters


    Test Parameters — BV-2.5 mm² (green-yellow striped)
    No.Test ItemTest Condition / MethodRequirementType
    1Conductor DC resistanceGB/T 3956, 20 °C≤ 7.41 Ω/km (2.5 mm² Cu)Routine
    2Power-frequency withstand2.0 kV AC, 5 minNo breakdownRoutine
    3Thickness testMicrometerInsulation ≥ 0.8 mmRoutine
    4Dimensional checkMicrometerOD ≈ 3.6 mmRoutine
    5Flame retardancyGB/T 18380 / IEC 60332-1Self-extinguishingType
    6Heat ageing168 h at 100 °CNo cracking after bend testType
    7Cold bend test0 °C, mandrel 4×ODNo cracksType
    8Heat shock1 h at 150 °CNo crackingType
    9Insulation resistanceAt 500 V DC, 20 °C≥ 0.011 MΩ·kmType
    10Conductor continuityPer GB/T 3956Solid continuousRoutine
    11Colour checkVisualGreen-yellow striped insulation (IEC 60446)Routine
    12Marking checkVisualBV, 2.5, 450/750 V printedRoutine

    The Wire Cross Section Structure


    2.5mm2 Solid Copper Conductor Ground Earth Solid Thhn Flame Retardant


    BV-2.5 mm² (green-yellow striped) — Cross-Section Construction Diagram (Schematic)
    Building wire build-up: solid copper conductor → green-yellow striped PVC insulation · 450/750 V AC · finished Ø ≈ 3.6 mm · no outer sheath · PE protective earthing (IEC 60446)
    No.LayerMaterial / ConstructionNominal Thickness (mm)Diameter (mm)Function / Remarks
    1ConductorSolid round annealed copper wire, Class 1—1.78PE protective earthing; R ≤ 7.41 Ω/km at 20 °C
    2InsulationPolyvinyl chloride (PVC), green-yellow striped0.8≈ 3.6 (finished)Electrical insulation; 70 °C rated; IEC 60446 PE colour
    3(No sheath)———No outer sheath — insulation is the outer layer
    Key Dimensions & Properties (expanded)
    Finished cable diameter≈ 3.6mm1.78 + 2×0.8
    Approx. cable mass≈ 22kg/kmCu + PVC insulation
    Nominal voltage rating450/750V ACBuilding interior fixed wiring
    Max continuous conductor temp.70°CPVC rated
    Short-circuit temp. (≤5 s)160°CPVC limit
    Min installation temp.0°CPVC becomes brittle below 0 °C
    Min bending radius≥ 4 × OD ≈ 14mmFixed installation
    DC resistance @ 20 °C≤ 7.41Ω/km2.5 mm² Cu Class 1
    Insulation resistance≥ 0.011MΩ·kmPVC
    Routine test voltage (AC)2.0 kV / 5 min—Power-frequency withstand
    Air ampacity @ 30 °C≈ 24ASingle core, free air (est.)
    Flame retardancyGB/T 18380 / IEC 60332-1—Self-extinguishing
    Halogen-freeNo—PVC contains halogen
    UV resistanceNone—Indoor use only
    Schematic — not to exact scale. Finished Ø ≈ 3.6 mm and weight ≈ 22 kg/km from cross-referenced industry samples; conductor/insulation dimensions per GB/T 5023 and GB/T 3956; ampacity 24 A is an engineering estimate for single core in free air. BV is the standard Chinese building wire — solid copper conductor with PVC insulation, rated 450/750 V AC for interior fixed wiring. The green-yellow striped colour is the IEC 60446 / GB 7947 standard PE (protective earth) conductor colour and is reserved exclusively for protective earthing — it MUST NOT be used for any other purpose. Values marked (est.) require confirmation against the factory test certificate.

    Construction Description


    Construction Description — BV-2.5 mm² (green-yellow striped)
    Layer-by-layer building wire build-up · solid copper conductor / green-yellow striped PVC insulation · 450/750 V AC · finished Ø ≈ 3.6 mm · no outer sheath · PE protective earthing (IEC 60446 / GB 7947)
    1. Product Identity & Ratings
    BV-2.5 (green-yellow striped) is the standard Chinese copper PVC-insulated building wire rated 450/750 V AC for interior fixed wiring, built and tested per GB/T 5023 / JB/T 8734. This is the IEC 60446 / GB 7947 standard **PE (protective earth) conductor colour** — green-yellow striped. Unlike solid green (used for specific bonding applications), green-yellow striped is reserved EXCLUSIVELY for protective earthing and must never be used for any other purpose (phase, neutral, control). Finished diameter is about 3.6 mm, mass about 22 kg/km, supplied in 100 m coils.
    2. Solid Copper Conductor
    The 2.5 mm² conductor is a solid round annealed copper wire (Class 1) — a single 1.78 mm diameter wire, not stranded. This gives a maximum DC resistance of 7.41 Ω/km at 20 °C. The solid conductor is rigid and designed for fixed installation only — it should not be flexed repeatedly. For PE circuits, low loop resistance is critical to ensure protective devices operate during earth faults.
    3. Green-Yellow Striped PVC Insulation
    The solid conductor is fully enclosed in a 0.8 mm layer of PVC with green-yellow diagonal stripes. This single layer provides both electrical insulation and the outer jacket — there is no separate outer sheath. The PVC is rated for 70 °C continuous conductor temperature (short-circuit up to 160 °C for ≤ 5 s). The green-yellow striped colour is the internationally recognised PE conductor colour per IEC 60446 / GB 7947, providing unmistakable visual identification of the protective earthing conductor.
    4. No Outer Sheath
    Unlike power cables and PV cables, BV has no outer sheath — the PVC insulation IS the outer layer. This keeps the cable thin, light, and low-cost for building wiring. The insulation provides basic mechanical protection and electrical isolation, but the cable must be installed inside conduit, trunking, or wall conduit for additional mechanical protection. It is not suitable for direct burial or outdoor UV exposure.
    5. Site Handling & Operational Notes
    • Install inside conduit, trunking, or wall conduit — do not leave exposed outdoors. • Observe the 4 × OD minimum bend radius (≈ 14 mm). • Service range 0 to +70 °C; conductor up to 70 °C continuous. • Routine test 2.0 kV AC / 5 min. • PVC contains halogen — not suitable for low-smoke halogen-free requirements (use WDZ-BYJ for LSZH). • At about 2.2 kg per 100 m, the cable is supplied in 100 m coils. • **CRITICAL: green-yellow striped is PE ONLY — never use for phase, neutral, or control.** • Use earth lugs / socket earth terminals for low-resistance bonding.

    8. Company Display





    9. Packaging, Storage & Logistics. Standard delivery is 100 m per coil. Each coil carries continuous marking: BV, 2.5 mm², 450/750 V, GB/T 5023, supplier identity, production year, and sequential metre marks. Storage should be in dry, indoor premises at 0 to +40 °C, protected from UV and moisture.



    10. Procurement Specification. State "BV-2.5 mm² green-yellow, 450/750 V" together with the required length. Always install inside conduit or trunking — never outdoors. For low-smoke halogen-free earthing in public buildings, specify WDZ-BYJ-2.5 green-yellow instead. Do not use green-yellow striped for any purpose other than PE protective earth. Use earth lugs / socket PE terminals for low-resistance

    bonding.


    11. Cable Industry FAQ.

    • Q1: Why is green-yellow striped used for PE? The green-yellow diagonal stripe is the internationally recognised PE (protective earth) conductor colour per IEC 60446 / GB 7947. It provides unmistakable visual identification — you can always tell the earthing wire apart from phase and neutral conductors.
    • Q2: What is the difference between green and green-yellow striped? Green-yellow striped is the IEC-standard PE conductor — reserved EXCLUSIVELY for protective earthing. Solid green may be used for specific bonding or earthing applications per local codes, but it is not the standard PE colour.
    • Q3: Can I use green-yellow striped as a neutral? NO — absolutely not. Green-yellow striped is reserved for PE protective earth only. Using it as a neutral or phase conductor is a serious safety violation.
    • Q4: What happens if I misidentify PE as a phase? If PE is accidentally used as a live conductor, the metal casing of electrical equipment will become live during an earth fault. The green-yellow stripe prevents this.
    • Q5: What size PE conductor do I need? For 2.5 mm² phase conductors, the PE conductor may be the same size (2.5 mm²) if mechanically protected, or 4 mm² if unprotected. For larger phase conductors, see GB 16895 / IEC 60364-5-54.
    • Q6: Can green-yellow striped be used for signal earthing? Yes — it is commonly used for equipment metal casing grounding and signal reference earthing.
    • Q7: Why use solid copper instead of stranded? Solid copper (Class 1) is cheaper, stiffer, and ideal for fixed installation in conduit and trunking. It should not be flexed repeatedly — for flexing applications, use BVR (stranded flexible).
    • Q8: Can BV be used outdoors? No — BV is designed for indoor dry locations only. The PVC insulation is not UV-resistant and will degrade when exposed to sunlight.
    • Q9: What is the earth fault loop impedance? The PE conductor must have sufficiently low resistance to ensure the protective device (MCB/RCD) operates within the required time during an earth fault. This is calculated per GB 16895 / IEC 60364.
    • Q10: What is the difference between PE and neutral? Neutral (blue) carries current under normal balanced conditions. PE (green-yellow) carries NO current under normal conditions — it only carries fault current during an earth fault. They must never be connected together.
    • Q11: What earth lug should I use? Use standard copper earth lugs (crimp or screw type) sized for 2.5 mm² solid conductor. Ensure the lug is tightened to the correct torque and protected from corrosion.