Sign In | Join Free | My burrillandco.com
Home > Solid Copper Conductor >

Blue BV Solid Copper Conductor 2.5mm2 Copper Wire Solid For Household Electrical

Anhui Tongdu International Trade Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Blue BV Solid Copper Conductor 2.5mm2 Copper Wire Solid For Household Electrical from wholesalers
     
    Buy cheap Blue BV Solid Copper Conductor 2.5mm2 Copper Wire Solid For Household Electrical from wholesalers
    • Buy cheap Blue BV Solid Copper Conductor 2.5mm2 Copper Wire Solid For Household Electrical from wholesalers

    Blue BV Solid Copper Conductor 2.5mm2 Copper Wire Solid For Household Electrical

    Ask Lasest Price
    Supply Ability : 100000 meters per month
    Brand Name : TONGDU
    Model Number : BV-2.5mm²
    Payment Terms : L/C,T/T
    Delivery Time : Less than 15 days
    Certification : CE/ISO/CCC
    • Product Details
    • Company Profile

    Blue BV Solid Copper Conductor 2.5mm2 Copper Wire Solid For Household Electrical

    Blue BV 2.5mm² PVC Copper Conductor Neutral Wire Household Electrical Wiring

    Cable Designation & Meaning

    Code

    Meaning

    B

    Fixed wiring cable (Class B — building wire)

    V

    PVC (polyvinyl chloride) insulation

    2.5 mm²

    Nominal cross-sectional area of conductor


    Construction: Plain copper conductor (solid or stranded), PVC insulation, single-core non-sheathed building wire.

    Applicable Standards

    • GB/T 5023-2008 / IEC 60227 — Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V
    • GB/T 3956 / IEC 60228 — Conductors (Class 1 solid or Class 2 stranded, copper)
    • GB/T 18380 / IEC 60332 — Flame retardant tests
    • GB/T 2951 / IEC 60811 — Insulating and sheathing materials — Common test methods

    BV-2.5 mm² (blue, neutral N / phase L3 / low-voltage control) — Copper PVC-Insulated Building Wire Specification & Engineering Data

    1. Product Overview & Rating Summary. BV-2.5 (blue) is the standard Chinese copper PVC-insulated building wire rated 450/750 V AC for interior fixed wiring, built and tested per GB/T 5023 / JB/T 8734. Unlike the yellow variant (three-phase L2 / bonding / alarm indicator), this blue version is the standard neutral N / three-phase phase L3 / low-voltage control conductor, designed for neutral N circuits, three-phase phase L3, and low-voltage control circuits. The blue colour provides clear visual distinction in neutral and control wiring systems. Finished diameter is about 3.6 mm, mass about 22 kg/km, supplied in 100 m coils.


    2. Layer-by-Layer Construction (Conductor to Outer).

    LayerConstructionWallDiameter
    ConductorSolid round annealed copper wire, Class 1—1.78 mm
    InsulationPolyvinyl chloride (PVC), blue0.8 mm≈ 3.6 mm (finished)
    Outer sheathNone — insulation is the outer layer——

    3. Electrical Characteristics. The 2.5 mm² conductor is a solid 1.78 mm annealed copper wire (Class 1, not stranded), giving a maximum DC resistance of 7.41 Ω/km at 20 °C. Routine proof is 2.0 kV AC / 5 minutes. Insulation resistance ≥ 0.011 MΩ·km. With the single core in free air at 30 °C, reference loading is about 24 A; in conduit with three grouped cores, the rating derates to about 19 A. The voltage drop on a 100 m single-phase loop at 24 A is about 3.6 V. Conductor loss at 24 A is about 4.3 W per metre at 70 °C.

    Insulation Data

    Property

    Value

    Material

    PVC (polyvinyl chloride)

    Nominal thickness

    0.8 mm

    Long-term service temp.

    70 °C (continuous)

    Short-circuit temp. (≤5 s)

    160 °C​ (Cu conductor limit per IEC 60228)

    Emergency overload temp.

    90 °C (short term)

    Weather resistance

    Limited — for indoor/dry use only; not UV-resistant

    Flame retardant

    GB/T 18380.3 Category C (ZC) available; standard version passes IEC 60332-1

    Smoke density

    Standard (non-low-smoke)

    Halogen content

    Contains halogen (PVC)

    Corrosivity

    Corrosive (PVC)

    Electrical Parameters

    Parameter

    Value

    Note

    Rated voltage U₀/U

    450 / 750 V

    GB/T 5023 / IEC 60227

    Test voltage AC (50 Hz, 5 min)

    2500 V

    Routine test

    DC resistance @20 °C

    ≤ 7.41 Ω/km

    GB/T 3956 Class 1 max, 2.5 mm² (solid Cu)

    AC resistance @70 °C (est.)

    ≈ 9.40 Ω/km

    per core

    Capacitance (approx.)

    negligible

    single-core building wire

    Inductive reactance (approx.)

    negligible

    —

    Current rating in conduit (30 °C ambient)

    24 A​

    single-phase, 2-core circuit (GB/T 16895)

    Current rating in free air (30 °C)

    27 A​

    single cable

    Current rating buried (20 °C)

    22 A​

    direct in soil (not recommended)

    Short-circuit current (1 s, Cu, 160 °C)

    ≈ 0.25 kA (250 A)

    2.5 mm² Cu

    Frequency

    50/60 Hz AC

    —

    Reference values: 2.5 mm² Cu at 24 A, single-phase 230 V → max load ≈ 5.5 kW. Voltage drop at 24 A ≈ 17.8 V/km per core (≈0.78% per 10 m at 230 V).

    Temperature Characteristics

    Property

    Value

    Max. conductor operating temp.

    70 °C (continuous)

    Max. short-circuit temp. (≤5 s)

    160 °C (Cu conductor)

    Emergency overload temp.

    90 °C (short term)

    Min. installation ambient temp.

    0 °C (PVC insulation); below 0 °C pre-heating required

    Service ambient range

    −15 °C to +70 °C (indoor/dry)

    Fire survival

    Standard (non-fire-rated); optional fire-resistant version available (BTTZ, BTTRZ)


    4. Thermal Response & Flame Behaviour. PVC insulation sustains a 70 °C continuous conductor temperature, with short-circuit capability up to 160 °C for ≤ 5 s. The cable is rated for service ambients between 0 °C and +70 °C and must not be installed below 0 °C (PVC becomes brittle). It is flame-retardant to GB/T 18380 / IEC 60332-1 (self-extinguishing). PVC contains halogen — not halogen-free; for low-smoke halogen-free control systems in public buildings, use WDZ-BYJ instead.

    Fire Performance (BV — Standard)

    Property

    Value / Requirement

    Flame retardant

    GB/T 18380.3 Category C (ZC), Category B (ZB) available

    Halogen content

    Contains halogen (PVC insulation)

    Smoke density

    Standard (non-low-smoke)

    Corrosivity

    Corrosive (PVC)

    Fire survival (circuit integrity)

    Not applicable (standard version); use mineral-insulated or fire-resistant building wire


    5. Installation Practice & Handling. Minimum bend radius is 4 × OD (≈ 14 mm) for fixed installation. The solid conductor is rigid and designed for fixed installation only. Install inside conduit, trunking, or wall conduit — do not leave exposed outdoors. Use standard screw terminals, crimp lugs, or wire nuts — no MC4 connectors needed. Blue colour = neutral N / L3 / control; match phase L1 (red/black), phase L2 (yellow), and protective earth (green/yellow) per local wiring codes. Laying temperature must not fall below 0 °C.

    Mechanical & Installation Parameters

    Parameter

    Value

    Remarks

    Minimum bending radius

    ≥ 4 × OD → ≈ 14 mm at Ø3.5 mm

    static installation

    Max. pulling tension

    100 N

    solid Cu conductor, avoid sharp bends

    Conduit ID

    ≥ 1.5 × OD → ≥ 5.3 mm; use 16 mm or 20 mm conduit

    standard building conduit

    Fixing

    cable clips, conduit, trunking

    —

    Impact resistance

    Low

    not armoured; protect with conduit

    Water resistance

    Poor

    indoor/dry locations only

    UV resistance

    Poor

    not for outdoor exposed use

    Termination note

    Strip insulation 10–12 mm; use standard copper lugs or screw terminals

    solid conductor requires careful handling to avoid breakage


    6. Typical Service Applications. This blue BV-2.5 is the standard neutral/control wire for: neutral N circuits, three-phase phase L3, low-voltage control circuits, weak-current systems, neutral busbar wiring, 24V/36V control circuits. Unlike the yellow variant (three-phase L2 and bonding), blue is chosen where neutral N or phase L3 colour coding matters — in neutral busbar wiring, weak-current systems, and low-voltage control circuits. It is installed inside conduit or trunking — never outdoors.



    7. Testing & Quality Assurance Regime. Routine tests on every coil include conductor DC resistance ≤ 7.41 Ω/km at 20 °C, the 2.0 kV AC / 5 min withstand, dimensional check (insulation ≥ 0.8 mm; OD ≈ 3.6 mm), and visual marking. Type tests include heat ageing (100 °C / 168 h), cold bend at 0 °C, heat shock at 150 °C, flame retardancy per GB/T 18380 / IEC 60332-1, insulation resistance, conductor continuity, and colour check (blue).


    The Wire Parameters


    BV-2.5 mm² (blue) — Copper PVC-Insulated Building Wire — Full Parameter Sheet
    Copper PVC-insulated building wire · solid Class 1 conductor / blue PVC insulation · 450/750 V AC · neutral N / phase L3 / low-voltage control · GB/T 5023 / JB/T 8734 · finished Ø ≈ 3.6 mm
    SectionParameterValueUnitRemarks / Standard
    01 · Identification
    Cable typeBV (Copper PVC-insulated building wire)—Neutral N / phase L3 / control, single core
    Rated voltage (U0/U)450/750V ACFor building interior fixed wiring
    Number of cores1 × 2.5—Single core
    Conductor materialAnnealed solid copper—Class 1 solid per GB/T 3956
    Insulation materialPolyvinyl chloride (PVC)—PVC-70 °C grade, blue pigment
    Outer sheathNone—Single-layer insulation, no outer sheath
    ColourBlue—Standard neutral N / phase L3 conductor colour
    StandardGB/T 5023 / JB/T 8734—Chinese building wire standard
    02 · Conductor (Solid Copper)
    Conductor typeSolid round copper wire—Class 1 solid per GB/T 3956
    Conductor diameter1.78mmSolid single wire
    Cross-sectional area2.5mm²Nominal
    DC resistance @ 20 °C≤ 7.41Ω/kmMaximum per GB/T 3956
    Conductor screenNone—LV building wire
    Conductor weight per km≈ 22kg/kmCopper density 8.89 g/cm³
    03 · Insulation (PVC)
    Insulation typePolyvinyl chloride (PVC)—PVC-70 °C grade, blue pigment
    Insulation thickness0.8mmNominal
    Finished outer diameter≈ 3.6mm1.78 + 2×0.8
    ColourBlue—Standard neutral N / phase L3 conductor colour
    Outer sheathNone—No outer sheath — insulation is the outer layer
    04 · Electrical
    Rated voltage (AC)450/750VFor building interior fixed wiring
    DC resistance @ 20 °C≤ 7.41Ω/km2.5 mm² Cu Class 1
    Insulation resistance≥ 0.011MΩ·kmPVC at 20 °C
    Conductor loss (at 24 A)≈ 4.3W/mI²R at 70 °C
    Routine test voltage (AC)2.0 kV / 5 min—Power-frequency withstand
    Voltage test (AC)2.5 kV / 5 min—AC withstand test
    05 · Thermal
    Max continuous conductor temp.70°CPVC rated
    Short-circuit temp.160°CPVC limit (≤ 5 s)
    Min installation temp.0°CPVC becomes brittle below 0 °C
    Service ambient range0 to +70°CIndoor dry locations
    UV resistanceNone—Indoor use only — not UV resistant
    Ozone resistanceLimited—Indoor use only
    Halogen-freeNo—PVC contains halogen
    Flame retardancyIEC 60332-1 / GB/T 18380—Self-extinguishing
    06 · Mechanical
    Min bending radius (fixed)≥ 4 × OD ≈ 14mmFixed installation
    Tensile strength (insulation)≥ 10.0MPaPVC insulation
    Abrasion resistanceGood—Indoor conduit / trunking
    Oil / fuel resistanceNo—Indoor dry locations only
    07 · Ampacity
    Air ampacity (open, 30 °C)≈ 24ASingle core, free air (est.)
    Conduit ampacity (3-core)≈ 19AIn conduit, grouped
    Voltage drop (per 100 m @ 24 A)≈ 1.8VSingle-phase loop ≈ 3.6 V
    08 · Installation
    Laying methodsConduit, trunking, wall conduit, neutral wiring, control circuits—Indoor fixed installation
    ConnectorsScrew terminals, crimp lugs, wire nuts—Standard building wiring
    PolarityColour-coded—Blue = neutral N / phase L3 / control
    Special toolsWire cutter, stripper, screwdriver—Standard electrical tools
    09 · Packing
    Standard supply length100 m / coilmBuilding wire
    Reel / packing typeCoil / carton—Standard packaging
    Surface markingBV, 2.5 mm², 450/750 V, GB/T 5023, metre marks—Continuous printing
    Storage conditionsDry, indoor, 0 to +40 °C—Protect from UV / moisture
    10 · Applications
    Typical useNeutral N circuits, three-phase phase L3, low-voltage control circuits, weak-current systems, neutral busbar wiring, 24V/36V control circuits—Indoor fixed wiring
    Max system voltage750V AC450/750 V rated
    Circuit current ratingUp to 24APer circuit breaker

    The Wire Test Parameters


    Test Parameters — BV-2.5 mm² (blue)
    No.Test ItemTest Condition / MethodRequirementType
    1Conductor DC resistanceGB/T 3956, 20 °C≤ 7.41 Ω/km (2.5 mm² Cu)Routine
    2Power-frequency withstand2.0 kV AC, 5 minNo breakdownRoutine
    3Thickness testMicrometerInsulation ≥ 0.8 mmRoutine
    4Dimensional checkMicrometerOD ≈ 3.6 mmRoutine
    5Flame retardancyGB/T 18380 / IEC 60332-1Self-extinguishingType
    6Heat ageing168 h at 100 °CNo cracking after bend testType
    7Cold bend test0 °C, mandrel 4×ODNo cracksType
    8Heat shock1 h at 150 °CNo crackingType
    9Insulation resistanceAt 500 V DC, 20 °C≥ 0.011 MΩ·kmType
    10Conductor continuityPer GB/T 3956Solid continuousRoutine
    11Colour checkVisualBlue insulationRoutine
    12Marking checkVisualBV, 2.5, 450/750 V printedRoutine

    The Wire Cross Section Structure


    Blue BV Solid Copper Conductor 2.5mm2 Copper Wire Solid For Household Electrical


    BV-2.5 mm² (blue) — Cross-Section Construction Diagram (Schematic)
    Building wire build-up: solid copper conductor → blue PVC insulation · 450/750 V AC · finished Ø ≈ 3.6 mm · no outer sheath · neutral N / phase L3
    No.LayerMaterial / ConstructionNominal Thickness (mm)Diameter (mm)Function / Remarks
    1ConductorSolid round annealed copper wire, Class 1—1.78Neutral N / L3; R ≤ 7.41 Ω/km at 20 °C
    2InsulationPolyvinyl chloride (PVC), blue0.8≈ 3.6 (finished)Electrical insulation; 70 °C rated
    3(No sheath)———No outer sheath — insulation is the outer layer
    Key Dimensions & Properties (expanded)
    Finished cable diameter≈ 3.6mm1.78 + 2×0.8
    Approx. cable mass≈ 22kg/kmCu + PVC insulation
    Nominal voltage rating450/750V ACBuilding interior fixed wiring
    Max continuous conductor temp.70°CPVC rated
    Short-circuit temp. (≤5 s)160°CPVC limit
    Min installation temp.0°CPVC becomes brittle below 0 °C
    Min bending radius≥ 4 × OD ≈ 14mmFixed installation
    DC resistance @ 20 °C≤ 7.41Ω/km2.5 mm² Cu Class 1
    Insulation resistance≥ 0.011MΩ·kmPVC
    Routine test voltage (AC)2.0 kV / 5 min—Power-frequency withstand
    Air ampacity @ 30 °C≈ 24ASingle core, free air (est.)
    Flame retardancyGB/T 18380 / IEC 60332-1—Self-extinguishing
    Halogen-freeNo—PVC contains halogen
    UV resistanceNone—Indoor use only
    Schematic — not to exact scale. Finished Ø ≈ 3.6 mm and weight ≈ 22 kg/km from cross-referenced industry samples; conductor/insulation dimensions per GB/T 5023 and GB/T 3956; ampacity 24 A is an engineering estimate for single core in free air. BV is the standard Chinese building wire — solid copper conductor with PVC insulation, rated 450/750 V AC for interior fixed wiring. The blue colour is commonly used for neutral N circuits, three-phase phase L3, and low-voltage control circuits. Unlike the yellow variant (three-phase L2 / bonding / alarm indicator), blue is chosen where neutral N or phase L3 colour coding matters. Values marked (est.) require confirmation against the factory test certificate.

    Construction Description


    Construction Description — BV-2.5 mm² (blue)
    Layer-by-layer building wire build-up · solid copper conductor / blue PVC insulation · 450/750 V AC · finished Ø ≈ 3.6 mm · no outer sheath · neutral N / phase L3
    1. Product Identity & Ratings
    BV-2.5 (blue) is the standard Chinese copper PVC-insulated building wire rated 450/750 V AC for interior fixed wiring, built and tested per GB/T 5023 / JB/T 8734. Unlike the yellow variant (three-phase L2 / bonding / alarm indicator), this blue version is the standard **neutral N / three-phase phase L3 / low-voltage control conductor**, designed for neutral N circuits, three-phase phase L3, and low-voltage control circuits. The blue colour provides clear visual distinction in neutral and control wiring systems. Finished diameter is about 3.6 mm, mass about 22 kg/km, supplied in 100 m coils.
    2. Solid Copper Conductor
    The 2.5 mm² conductor is a solid round annealed copper wire (Class 1) — a single 1.78 mm diameter wire, not stranded. This gives a maximum DC resistance of 7.41 Ω/km at 20 °C. The solid conductor is rigid and designed for fixed installation only — it should not be flexed repeatedly. The copper is annealed for conductivity, not tinned (unlike PV cables, which use tinned strands for outdoor corrosion resistance).
    3. Blue PVC Insulation
    The solid conductor is fully enclosed in a 0.8 mm layer of blue polyvinyl chloride (PVC). This single layer provides both electrical insulation and the outer jacket — there is no separate outer sheath (unlike PV cables' double-layer construction). The PVC is rated for 70 °C continuous conductor temperature (short-circuit up to 160 °C for ≤ 5 s). The blue colour is the standard neutral N / phase L3 conductor colour, providing clear visual distinction from phase L1 (red/black) and phase L2 (yellow).
    4. No Outer Sheath
    Unlike power cables and PV cables, BV has no outer sheath — the PVC insulation IS the outer layer. This keeps the cable thin, light, and low-cost for building wiring. The insulation provides basic mechanical protection and electrical isolation, but the cable must be installed inside conduit, trunking, or wall conduit for additional mechanical protection. It is not suitable for direct burial or outdoor UV exposure.
    5. Site Handling & Operational Notes
    • Install inside conduit, trunking, or wall conduit — do not leave exposed outdoors. • Observe the 4 × OD minimum bend radius (≈ 14 mm). • Service range 0 to +70 °C; conductor up to 70 °C continuous. • Routine test 2.0 kV AC / 5 min. • PVC contains halogen — not suitable for low-smoke halogen-free requirements (use WDZ-BYJ for LSZH). • At about 2.2 kg per 100 m, the cable is supplied in 100 m coils. • Blue colour = neutral N / L3 / control; match phase L1 (red/black), phase L2 (yellow), and protective earth (green/yellow) per local wiring codes. • Use standard screw terminals, crimp lugs, or wire nuts — no MC4 connectors needed.

    8. Company Display





    9. Packaging, Storage & Logistics. Standard delivery is 100 m per coil. Each coil carries continuous marking: BV, 2.5 mm², 450/750 V, GB/T 5023, supplier identity, production year, and sequential metre marks. Storage should be in dry, indoor premises at 0 to +40 °C, protected from UV and moisture.



    10. Procurement Specification. State "BV-2.5 mm² blue, 450/750 V" together with the required length. Always install inside conduit or trunking — never outdoors. For low-smoke halogen-free control systems in public buildings, specify WDZ-BYJ-2.5 blue instead. Match blue neutral N / L3 with phase L1 (red/black), phase L2 (yellow), and green/yellow protective earth per local wiring codes.


    11. Cable Industry FAQ.

    • Q1: Why use blue instead of yellow for this application? Blue is the standard neutral N / phase L3 / low-voltage control conductor colour. Yellow is used for three-phase L2 / bonding / alarm indicator. In wiring systems, blue provides clear visual distinction between neutral N, phase L3, and control circuits.
    • Q2: What is the difference between blue and yellow BV-2.5? Electrically and mechanically identical — same conductor, same insulation, same voltage rating, same ampacity. The only difference is colour and typical application: blue = neutral N / L3 / low-voltage control; yellow = three-phase L2 / bonding / alarm indicator.
    • Q3: Can blue BV-2.5 be used as neutral N? Yes — blue is the standard neutral conductor colour in most wiring conventions. It is used for the neutral return path in single-phase and three-phase circuits.
    • Q4: Can blue BV-2.5 be used for 24V/36V control circuits? Yes — blue is commonly used for low-voltage control circuits (24V/36V), providing visual distinction from power circuits.
    • Q5: What is the difference between blue and white BV-2.5? Electrically identical. White = general-purpose; blue = neutral N / L3 / control. Choose the colour based on the circuit's role in the wiring system.
    • Q6: Why use solid copper instead of stranded? Solid copper (Class 1) is cheaper, stiffer, and ideal for fixed installation in conduit and trunking. It should not be flexed repeatedly — for flexing applications, use BVR (stranded flexible).
    • Q7: Can BV be used outdoors? No — BV is designed for indoor dry locations only. The PVC insulation is not UV-resistant and will degrade when exposed to sunlight.
    • Q8: Why is the temperature rating only 70 °C? PVC insulation softens at higher temperatures. For higher temperature rating, use BV-90 or BYJ (XLPE-insulated building wire).
    • Q9: What is the maximum circuit current? About 24 A in free air; in conduit with grouped cables, derate to about 19 A. For neutral N circuits, the neutral current depends on circuit balance; for 24V/36V control circuits, the actual current is typically below 5 A.
    • Q10: Can blue BV-2.5 be used for weak-current systems? Yes — blue is commonly used for weak-current system wiring (e.g. sensor circuits, communication control), providing visual distinction from power circuits.
    • Q11: What is BVR? BVR is the stranded (flexible) version of BV — same PVC insulation and voltage rating, but uses stranded copper conductor instead of solid. BVR is used where flexibility is needed (e.g. behind control panels where wires must bend around terminals).
    Quality Blue BV Solid Copper Conductor 2.5mm2 Copper Wire Solid For Household Electrical for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Anhui Tongdu International Trade Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Find Similar Products By Category: