    Red Solid Copper Conductor PVC Insulated Single Core Copper Live Wire

    Ask Lasest Price
    Brand Name : TONGDU
    Supply Ability : 100000 meters per month
    Delivery Time : Less than 15 days
    Certification : CE/ISO/CCC
    Model Number : BV-2.5mm²
    Payment Terms : L/C,T/T
    • Product Details
    • Company Profile

    Red Solid Copper Conductor PVC Insulated Single Core Copper Live Wire

    Red BV 2.5mm² PVC Insulated Single Core Copper Live Wire 450/750V Electrical Building Cable

    Cable Designation & Meaning

    Code

    Meaning

    B

    Fixed wiring cable (Class B — building wire)

    V

    PVC (polyvinyl chloride) insulation

    2.5 mm²

    Nominal cross-sectional area of conductor


    Construction: Plain copper conductor (solid or stranded), PVC insulation, single-core non-sheathed building wire.

    Applicable Standards

    • GB/T 5023-2008 / IEC 60227 — Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V
    • GB/T 3956 / IEC 60228 — Conductors (Class 1 solid or Class 2 stranded, copper)
    • GB/T 18380 / IEC 60332 — Flame retardant tests
    • GB/T 2951 / IEC 60811 — Insulating and sheathing materials — Common test methods

    BV-2.5 mm² (red, switch control / emergency circuit) — Copper PVC-Insulated Building Wire Specification & Engineering Data

    1. Product Overview & Rating Summary. BV-2.5 (red) is the standard Chinese copper PVC-insulated building wire rated 450/750 V AC for interior fixed wiring, built and tested per GB/T 5023 / JB/T 8734. Unlike the black variant (industrial switchboard phase L1), this red version is the standard switch control / emergency circuit conductor, designed for switch control circuits, emergency lighting circuits, fire alarm circuits, and residential phase L1 wiring. The red colour provides instant visual identification of control and emergency circuits during installation and maintenance. Finished diameter is about 3.6 mm, mass about 22 kg/km, supplied in 100 m coils.


    2. Layer-by-Layer Construction (Conductor to Outer).

    LayerConstructionWallDiameter
    ConductorSolid round annealed copper wire, Class 1—1.78 mm
    InsulationPolyvinyl chloride (PVC), red0.8 mm≈ 3.6 mm (finished)
    Outer sheathNone — insulation is the outer layer——

    3. Electrical Characteristics. The 2.5 mm² conductor is a solid 1.78 mm annealed copper wire (Class 1, not stranded), giving a maximum DC resistance of 7.41 Ω/km at 20 °C. Routine proof is 2.0 kV AC / 5 minutes. Insulation resistance ≥ 0.011 MΩ·km. With the single core in free air at 30 °C, reference loading is about 24 A; in conduit with three grouped cores, the rating derates to about 19 A. The voltage drop on a 100 m single-phase loop at 24 A is about 3.6 V. Conductor loss at 24 A is about 4.3 W per metre at 70 °C.

    Insulation Data

    Property

    Value

    Material

    PVC (polyvinyl chloride)

    Nominal thickness

    0.8 mm

    Long-term service temp.

    70 °C (continuous)

    Short-circuit temp. (≤5 s)

    160 °C​ (Cu conductor limit per IEC 60228)

    Emergency overload temp.

    90 °C (short term)

    Weather resistance

    Limited — for indoor/dry use only; not UV-resistant

    Flame retardant

    GB/T 18380.3 Category C (ZC) available; standard version passes IEC 60332-1

    Smoke density

    Standard (non-low-smoke)

    Halogen content

    Contains halogen (PVC)

    Corrosivity

    Corrosive (PVC)

    Electrical Parameters

    Parameter

    Value

    Note

    Rated voltage U₀/U

    450 / 750 V

    GB/T 5023 / IEC 60227

    Test voltage AC (50 Hz, 5 min)

    2500 V

    Routine test

    DC resistance @20 °C

    ≤ 7.41 Ω/km

    GB/T 3956 Class 1 max, 2.5 mm² (solid Cu)

    AC resistance @70 °C (est.)

    ≈ 9.40 Ω/km

    per core

    Capacitance (approx.)

    negligible

    single-core building wire

    Inductive reactance (approx.)

    negligible

    —

    Current rating in conduit (30 °C ambient)

    24 A​

    single-phase, 2-core circuit (GB/T 16895)

    Current rating in free air (30 °C)

    27 A​

    single cable

    Current rating buried (20 °C)

    22 A​

    direct in soil (not recommended)

    Short-circuit current (1 s, Cu, 160 °C)

    ≈ 0.25 kA (250 A)

    2.5 mm² Cu

    Frequency

    50/60 Hz AC

    —

    Reference values: 2.5 mm² Cu at 24 A, single-phase 230 V → max load ≈ 5.5 kW. Voltage drop at 24 A ≈ 17.8 V/km per core (≈0.78% per 10 m at 230 V).

    Temperature Characteristics

    Property

    Value

    Max. conductor operating temp.

    70 °C (continuous)

    Max. short-circuit temp. (≤5 s)

    160 °C (Cu conductor)

    Emergency overload temp.

    90 °C (short term)

    Min. installation ambient temp.

    0 °C (PVC insulation); below 0 °C pre-heating required

    Service ambient range

    −15 °C to +70 °C (indoor/dry)

    Fire survival

    Standard (non-fire-rated); optional fire-resistant version available (BTTZ, BTTRZ)


    4. Thermal Response & Flame Behaviour. PVC insulation sustains a 70 °C continuous conductor temperature, with short-circuit capability up to 160 °C for ≤ 5 s. The cable is rated for service ambients between 0 °C and +70 °C and must not be installed below 0 °C (PVC becomes brittle). It is flame-retardant to GB/T 18380 / IEC 60332-1 (self-extinguishing). PVC contains halogen — not halogen-free; for low-smoke halogen-free emergency circuit applications, use WDZ-BYJ instead.

    Fire Performance (BV — Standard)

    Property

    Value / Requirement

    Flame retardant

    GB/T 18380.3 Category C (ZC), Category B (ZB) available

    Halogen content

    Contains halogen (PVC insulation)

    Smoke density

    Standard (non-low-smoke)

    Corrosivity

    Corrosive (PVC)

    Fire survival (circuit integrity)

    Not applicable (standard version); use mineral-insulated or fire-resistant building wire


    5. Installation Practice & Handling. Minimum bend radius is 4 × OD (≈ 14 mm) for fixed installation. The solid conductor is rigid and designed for fixed installation only. Install inside conduit, trunking, or wall conduit — do not leave exposed outdoors. Use standard screw terminals, crimp lugs, or wire nuts — no MC4 connectors needed. Red colour = switch control / emergency circuit; match neutral (blue/white) and protective earth (green/yellow) per local wiring codes. Laying temperature must not fall below 0 °C.

    Mechanical & Installation Parameters

    Parameter

    Value

    Remarks

    Minimum bending radius

    ≥ 4 × OD → ≈ 14 mm at Ø3.5 mm

    static installation

    Max. pulling tension

    100 N

    solid Cu conductor, avoid sharp bends

    Conduit ID

    ≥ 1.5 × OD → ≥ 5.3 mm; use 16 mm or 20 mm conduit

    standard building conduit

    Fixing

    cable clips, conduit, trunking

    —

    Impact resistance

    Low

    not armoured; protect with conduit

    Water resistance

    Poor

    indoor/dry locations only

    UV resistance

    Poor

    not for outdoor exposed use

    Termination note

    Strip insulation 10–12 mm; use standard copper lugs or screw terminals

    solid conductor requires careful handling to avoid breakage


    6. Typical Service Applications. This red BV-2.5 is the standard control/emergency wire for: switch control circuits, emergency lighting circuits, fire alarm circuits, residential phase L1, lighting switch wiring, smoke detector circuits. Unlike the black variant (industrial switchboard and motor control), red is chosen where switch control or emergency circuit colour coding matters — in residential switch boxes, emergency lighting systems, and fire alarm circuits. It is installed inside conduit or trunking — never outdoors.



    7. Testing & Quality Assurance Regime. Routine tests on every coil include conductor DC resistance ≤ 7.41 Ω/km at 20 °C, the 2.0 kV AC / 5 min withstand, dimensional check (insulation ≥ 0.8 mm; OD ≈ 3.6 mm), and visual marking. Type tests include heat ageing (100 °C / 168 h), cold bend at 0 °C, heat shock at 150 °C, flame retardancy per GB/T 18380 / IEC 60332-1, insulation resistance, conductor continuity, and colour check (red).


    The Wire Parameters


    BV-2.5 mm² (red) — Copper PVC-Insulated Building Wire — Full Parameter Sheet
    Copper PVC-insulated building wire · solid Class 1 conductor / red PVC insulation · 450/750 V AC · switch control & emergency circuits · GB/T 5023 / JB/T 8734 · finished Ø ≈ 3.6 mm
    SectionParameterValueUnitRemarks / Standard
    01 · Identification
    Cable typeBV (Copper PVC-insulated building wire)—Switch control / emergency circuit, single core
    Rated voltage (U0/U)450/750V ACFor building interior fixed wiring
    Number of cores1 × 2.5—Single core
    Conductor materialAnnealed solid copper—Class 1 solid per GB/T 3956
    Insulation materialPolyvinyl chloride (PVC)—PVC-70 °C grade, red pigment
    Outer sheathNone—Single-layer insulation, no outer sheath
    ColourRed—Standard switch control / emergency circuit colour
    StandardGB/T 5023 / JB/T 8734—Chinese building wire standard
    02 · Conductor (Solid Copper)
    Conductor typeSolid round copper wire—Class 1 solid per GB/T 3956
    Conductor diameter1.78mmSolid single wire
    Cross-sectional area2.5mm²Nominal
    DC resistance @ 20 °C≤ 7.41Ω/kmMaximum per GB/T 3956
    Conductor screenNone—LV building wire
    Conductor weight per km≈ 22kg/kmCopper density 8.89 g/cm³
    03 · Insulation (PVC)
    Insulation typePolyvinyl chloride (PVC)—PVC-70 °C grade, red pigment
    Insulation thickness0.8mmNominal
    Finished outer diameter≈ 3.6mm1.78 + 2×0.8
    ColourRed—Standard switch control / emergency circuit colour
    Outer sheathNone—No outer sheath — insulation is the outer layer
    04 · Electrical
    Rated voltage (AC)450/750VFor building interior fixed wiring
    DC resistance @ 20 °C≤ 7.41Ω/km2.5 mm² Cu Class 1
    Insulation resistance≥ 0.011MΩ·kmPVC at 20 °C
    Conductor loss (at 24 A)≈ 4.3W/mI²R at 70 °C
    Routine test voltage (AC)2.0 kV / 5 min—Power-frequency withstand
    Voltage test (AC)2.5 kV / 5 min—AC withstand test
    05 · Thermal
    Max continuous conductor temp.70°CPVC rated
    Short-circuit temp.160°CPVC limit (≤ 5 s)
    Min installation temp.0°CPVC becomes brittle below 0 °C
    Service ambient range0 to +70°CIndoor dry locations
    UV resistanceNone—Indoor use only — not UV resistant
    Ozone resistanceLimited—Indoor use only
    Halogen-freeNo—PVC contains halogen
    Flame retardancyIEC 60332-1 / GB/T 18380—Self-extinguishing
    06 · Mechanical
    Min bending radius (fixed)≥ 4 × OD ≈ 14mmFixed installation
    Tensile strength (insulation)≥ 10.0MPaPVC insulation
    Abrasion resistanceGood—Indoor conduit / trunking
    Oil / fuel resistanceNo—Indoor dry locations only
    07 · Ampacity
    Air ampacity (open, 30 °C)≈ 24ASingle core, free air (est.)
    Conduit ampacity (3-core)≈ 19AIn conduit, grouped
    Voltage drop (per 100 m @ 24 A)≈ 1.8VSingle-phase loop ≈ 3.6 V
    08 · Installation
    Laying methodsConduit, trunking, wall conduit, switch wiring, emergency circuits—Indoor fixed installation
    ConnectorsScrew terminals, crimp lugs, wire nuts—Standard building wiring
    PolarityColour-coded—Red = switch control / emergency circuit
    Special toolsWire cutter, stripper, screwdriver—Standard electrical tools
    09 · Packing
    Standard supply length100 m / coilmBuilding wire
    Reel / packing typeCoil / carton—Standard packaging
    Surface markingBV, 2.5 mm², 450/750 V, GB/T 5023, metre marks—Continuous printing
    Storage conditionsDry, indoor, 0 to +40 °C—Protect from UV / moisture
    10 · Applications
    Typical useSwitch control circuits, emergency lighting circuits, fire alarm circuits, residential phase L1, lighting switch wiring, smoke detector circuits—Indoor fixed wiring
    Max system voltage750V AC450/750 V rated
    Circuit current ratingUp to 24APer circuit breaker

    The Wire Test Parameters


    Test Parameters — BV-2.5 mm² (red)
    No.Test ItemTest Condition / MethodRequirementType
    1Conductor DC resistanceGB/T 3956, 20 °C≤ 7.41 Ω/km (2.5 mm² Cu)Routine
    2Power-frequency withstand2.0 kV AC, 5 minNo breakdownRoutine
    3Thickness testMicrometerInsulation ≥ 0.8 mmRoutine
    4Dimensional checkMicrometerOD ≈ 3.6 mmRoutine
    5Flame retardancyGB/T 18380 / IEC 60332-1Self-extinguishingType
    6Heat ageing168 h at 100 °CNo cracking after bend testType
    7Cold bend test0 °C, mandrel 4×ODNo cracksType
    8Heat shock1 h at 150 °CNo crackingType
    9Insulation resistanceAt 500 V DC, 20 °C≥ 0.011 MΩ·kmType
    10Conductor continuityPer GB/T 3956Solid continuousRoutine
    11Colour checkVisualRed insulationRoutine
    12Marking checkVisualBV, 2.5, 450/750 V printedRoutine

    The Wire Cross Section Structure


    Red Solid Copper Conductor PVC Insulated Single Core Copper Live Wire


    BV-2.5 mm² (red) — Cross-Section Construction Diagram (Schematic)
    Building wire build-up: solid copper conductor → red PVC insulation · 450/750 V AC · finished Ø ≈ 3.6 mm · no outer sheath · switch control / emergency circuit
    No.LayerMaterial / ConstructionNominal Thickness (mm)Diameter (mm)Function / Remarks
    1ConductorSolid round annealed copper wire, Class 1—1.78Switch control / emergency circuit; R ≤ 7.41 Ω/km at 20 °C
    2InsulationPolyvinyl chloride (PVC), red0.8≈ 3.6 (finished)Electrical insulation; 70 °C rated
    3(No sheath)———No outer sheath — insulation is the outer layer
    Key Dimensions & Properties (expanded)
    Finished cable diameter≈ 3.6mm1.78 + 2×0.8
    Approx. cable mass≈ 22kg/kmCu + PVC insulation
    Nominal voltage rating450/750V ACBuilding interior fixed wiring
    Max continuous conductor temp.70°CPVC rated
    Short-circuit temp. (≤5 s)160°CPVC limit
    Min installation temp.0°CPVC becomes brittle below 0 °C
    Min bending radius≥ 4 × OD ≈ 14mmFixed installation
    DC resistance @ 20 °C≤ 7.41Ω/km2.5 mm² Cu Class 1
    Insulation resistance≥ 0.011MΩ·kmPVC
    Routine test voltage (AC)2.0 kV / 5 min—Power-frequency withstand
    Air ampacity @ 30 °C≈ 24ASingle core, free air (est.)
    Flame retardancyGB/T 18380 / IEC 60332-1—Self-extinguishing
    Halogen-freeNo—PVC contains halogen
    UV resistanceNone—Indoor use only
    Schematic — not to exact scale. Finished Ø ≈ 3.6 mm and weight ≈ 22 kg/km from cross-referenced industry samples; conductor/insulation dimensions per GB/T 5023 and GB/T 3956; ampacity 24 A is an engineering estimate for single core in free air. BV is the standard Chinese building wire — solid copper conductor with PVC insulation, rated 450/750 V AC for interior fixed wiring. The red colour is commonly used for switch control circuits, emergency lighting circuits, fire alarm circuits, and residential phase L1 wiring. Unlike the black variant (industrial switchboard phase L1), red is chosen where switch control or emergency circuit colour coding matters. Values marked (est.) require confirmation against the factory test certificate.

    Construction Description


    Construction Description — BV-2.5 mm² (red)
    Layer-by-layer building wire build-up · solid copper conductor / red PVC insulation · 450/750 V AC · finished Ø ≈ 3.6 mm · no outer sheath · switch control / emergency circuit
    1. Product Identity & Ratings
    BV-2.5 (red) is the standard Chinese copper PVC-insulated building wire rated 450/750 V AC for interior fixed wiring, built and tested per GB/T 5023 / JB/T 8734. Unlike the black variant (industrial switchboard phase L1), this red version is the standard **switch control / emergency circuit conductor**, designed for switch control circuits, emergency lighting circuits, fire alarm circuits, and residential phase L1 wiring. The red colour provides instant visual identification of control and emergency circuits. Finished diameter is about 3.6 mm, mass about 22 kg/km, supplied in 100 m coils.
    2. Solid Copper Conductor
    The 2.5 mm² conductor is a solid round annealed copper wire (Class 1) — a single 1.78 mm diameter wire, not stranded. This gives a maximum DC resistance of 7.41 Ω/km at 20 °C. The solid conductor is rigid and designed for fixed installation only — it should not be flexed repeatedly. The copper is annealed for conductivity, not tinned (unlike PV cables, which use tinned strands for outdoor corrosion resistance).
    3. Red PVC Insulation
    The solid conductor is fully enclosed in a 0.8 mm layer of red polyvinyl chloride (PVC). This single layer provides both electrical insulation and the outer jacket — there is no separate outer sheath (unlike PV cables' double-layer construction). The PVC is rated for 70 °C continuous conductor temperature (short-circuit up to 160 °C for ≤ 5 s). The red colour is the standard switch control / emergency circuit conductor colour, providing instant visual identification during installation and maintenance.
    4. No Outer Sheath
    Unlike power cables and PV cables, BV has no outer sheath — the PVC insulation IS the outer layer. This keeps the cable thin, light, and low-cost for building wiring. The insulation provides basic mechanical protection and electrical isolation, but the cable must be installed inside conduit, trunking, or wall conduit for additional mechanical protection. It is not suitable for direct burial or outdoor UV exposure.
    5. Site Handling & Operational Notes
    • Install inside conduit, trunking, or wall conduit — do not leave exposed outdoors. • Observe the 4 × OD minimum bend radius (≈ 14 mm). • Service range 0 to +70 °C; conductor up to 70 °C continuous. • Routine test 2.0 kV AC / 5 min. • PVC contains halogen — not suitable for low-smoke halogen-free requirements (use WDZ-BYJ for LSZH). • At about 2.2 kg per 100 m, the cable is supplied in 100 m coils. • Red colour = switch control / emergency circuit; match neutral (blue/white) and protective earth (green/yellow) per local wiring codes. • Use standard screw terminals, crimp lugs, or wire nuts — no MC4 connectors needed.

    8. Company Display





    9. Packaging, Storage & Logistics. Standard delivery is 100 m per coil. Each coil carries continuous marking: BV, 2.5 mm², 450/750 V, GB/T 5023, supplier identity, production year, and sequential metre marks. Storage should be in dry, indoor premises at 0 to +40 °C, protected from UV and moisture.



    10. Procurement Specification. State "BV-2.5 mm² red, 450/750 V" together with the required length. Always install inside conduit or trunking — never outdoors. For low-smoke halogen-free emergency circuits (e.g. fire alarm systems in public buildings), specify WDZ-BYJ-2.5 red instead. Match red switch/emergency with neutral (blue/white) and green/yellow protective earth per local wiring codes.


    11. Cable Industry FAQ.

    • Q1: Why use red instead of black for this application? Red is the standard switch control / emergency circuit conductor colour. Black is used for industrial switchboard phase L1. In residential and commercial wiring, red provides instant visual identification of control and emergency circuits during installation and maintenance.
    • Q2: What is the difference between red and black BV-2.5? Electrically and mechanically identical — same conductor, same insulation, same voltage rating, same ampacity. The only difference is colour and typical application: red = switch control / emergency / fire alarm; black = industrial switchboard phase L1.
    • Q3: Can red BV-2.5 be used for fire alarm circuits? Yes — red is the standard fire alarm circuit colour in many wiring codes. However, for public buildings where low-smoke halogen-free is required, use WDZ-BYJ-2.5 red instead of PVC.
    • Q4: What is the difference between red and white BV-2.5? Electrically identical. White = neutral / general-purpose; red = switch control / emergency / phase L1. Choose the colour based on the circuit's role in the wiring system.
    • Q5: Can red BV-2.5 be used for emergency lighting? Yes — red is commonly used for emergency lighting circuits. However, emergency lighting circuits often require low-smoke halogen-free cables (WDZ-BYJ) in public buildings.
    • Q6: Why use solid copper instead of stranded? Solid copper (Class 1) is cheaper, stiffer, and ideal for fixed installation in conduit and switch boxes. It should not be flexed repeatedly — for flexing applications, use BVR (stranded flexible).
    • Q7: Can BV be used outdoors? No — BV is designed for indoor dry locations only. The PVC insulation is not UV-resistant and will degrade when exposed to sunlight.
    • Q8: Why is the temperature rating only 70 °C? PVC insulation softens at higher temperatures. For higher temperature rating, use BV-90 or BYJ (XLPE-insulated building wire).
    • Q9: What is the maximum circuit current? About 24 A in free air; in conduit with grouped cables, derate to about 19 A. For switch control and emergency circuits, the actual current is typically much lower (below 10 A).
    • Q10: Can red BV-2.5 be used for residential phase L1? Yes — in many residential wiring conventions, red is used for phase L1. Check local wiring codes for the required colour convention.
    • Q11: What is BVR? BVR is the stranded (flexible) version of BV — same PVC insulation and voltage rating, but uses stranded copper conductor instead of solid. BVR is used where flexibility is needed (e.g. behind switch boxes where wires must bend around terminals).